MeltDBWiki/RoundingMZ: Difference between revisions
Jump to navigation
Jump to search
imported>HeikoNeuweger No edit summary |
imported>HeikoNeuweger No edit summary |
||
Line 4: | Line 4: | ||
== Round m/z values of mass spectra to integral values == | == Round m/z values of mass spectra to integral values == | ||
* Several mass spectral databases contain mass spectra in nominal m/z notation whereas MS instruments are able to obtain higher resolution. | * Several mass spectral databases used for the identification of metabolites in GC/MS measurements (EI) contain mass spectra in nominal m/z notation whereas MS instruments are able to obtain higher resolution. | ||
* High resolution mass spectra can be compared to nominal m/z spectra by rounding the measured m/z values to integral values. | * The mass spectral lookup using e.g. the ''dot-product' of the query and database spectra is inaprropriate if high resolution spectra are compared to spectra with nominal m/z entries. One possibility is to transform the high resolution spectra to integral m/z values. Alternatively, adapted scoring methods can be applied. | ||
* High resolution mass spectra can be compared to nominal m/z spectra by ''rounding'' the measured m/z values to integral values. | |||
* It is questionable if ''rounding'' at 0.5 is the best option. | |||
* The KEGG compounds database contains more than 10000 compounds with annotated masses and most of the masses are below 1000 Dalton. | * The KEGG compounds database contains more than 10000 compounds with annotated masses and most of the masses are below 1000 Dalton. | ||
* C, H, N, O, P, S are the main atoms of | * C, H, N, O, P, S are the main atoms of biologically relevant compounds. | ||
[[Image:MeltDBWiki$$RoundingMZ$histweight.png]] | [[Image:MeltDBWiki$$RoundingMZ$histweight.png]] | ||
Line 15: | Line 17: | ||
[[Image:MeltDBWiki$$RoundingMZ$scatter.png]] | [[Image:MeltDBWiki$$RoundingMZ$scatter.png]] | ||
* In the fractional interval 0.7 to 0.75 only 15 compounds are listed in the KEGG compounds database. | |||
* Mass spectrometric devices may drift, meassured m/z values can therefore vary. | * Mass spectrometric devices may drift, meassured m/z values can therefore vary. | ||
* To round m/z to integral values as robust as possible, 0. | * To round m/z to integral values as robust as possible, 0.7 instead of 0.5 may be used. | ||
[[Image:MeltDBWiki$$RoundingMZ$histmz.png]] | [[Image:MeltDBWiki$$RoundingMZ$histmz.png]] | ||
* For all masses measured by a MS instrument (Ion Trap) during a complete chromatogram, the distribution of the values is comparable. | * For all masses measured by a MS instrument (EI, Ion Trap) during a complete chromatogram, the distribution of the values is comparable. | ||
* Again, in the fractional interval 0.7 to 0.75 only 0.3% of the m/z values are detected. | * Again, in the fractional interval 0.7 to 0.75 only 0.3% of the m/z values are detected. | ||
[[Image:MeltDBWiki$$RoundingMZ$mzfrac.png]] | [[Image:MeltDBWiki$$RoundingMZ$mzfrac.png]] | ||
* This observation is also useful if extracted ion chromatograms (EIC) of GC/MS measurements with integral m/z values need to be generated without following individual m/z traces. Again, a ''rounding'' of the m/z values at | * This observation is also useful if extracted ion chromatograms (EIC) of GC/MS measurements with integral m/z values need to be generated without following individual m/z traces. Again, a ''rounding'' of the m/z values at 0.7 instead of 0.5 will provide more stable EICs. | ||
[[Image:MeltDBWiki$$RoundingMZ$cdfhist.png]] | [[Image:MeltDBWiki$$RoundingMZ$cdfhist.png]] |
Revision as of 21:10, 10 April 2008
Round m/z values of mass spectra to integral values
- Several mass spectral databases used for the identification of metabolites in GC/MS measurements (EI) contain mass spectra in nominal m/z notation whereas MS instruments are able to obtain higher resolution.
- The mass spectral lookup using e.g. the dot-product' of the query and database spectra is inaprropriate if high resolution spectra are compared to spectra with nominal m/z entries. One possibility is to transform the high resolution spectra to integral m/z values. Alternatively, adapted scoring methods can be applied.
- High resolution mass spectra can be compared to nominal m/z spectra by rounding the measured m/z values to integral values.
- It is questionable if rounding at 0.5 is the best option.
- The KEGG compounds database contains more than 10000 compounds with annotated masses and most of the masses are below 1000 Dalton.
- C, H, N, O, P, S are the main atoms of biologically relevant compounds.
- The possible fractional values of the compound masses are dependent on the integral compound mass.
- In the fractional interval 0.7 to 0.75 only 15 compounds are listed in the KEGG compounds database.
- Mass spectrometric devices may drift, meassured m/z values can therefore vary.
- To round m/z to integral values as robust as possible, 0.7 instead of 0.5 may be used.
- For all masses measured by a MS instrument (EI, Ion Trap) during a complete chromatogram, the distribution of the values is comparable.
- Again, in the fractional interval 0.7 to 0.75 only 0.3% of the m/z values are detected.
- This observation is also useful if extracted ion chromatograms (EIC) of GC/MS measurements with integral m/z values need to be generated without following individual m/z traces. Again, a rounding of the m/z values at 0.7 instead of 0.5 will provide more stable EICs.