ProDBWiki/DeveloperDocumentation/ImportMultiScans
Import Multi Scans
Overview
If you have a gel picture with many protein spots from a tissue, and you want to know what kind of proteins that are, you take a sample from the spots and analyse them with mass spectrometry. As a result you get a file with the peptide masses. Now you have to import the files and connect them with the corresponding gel spot. This is a lot of work, especially if you have a large number of spots/files. Therefore you can use the Multi Files Importer. Here you can import all files from spots from one gel at once. You save all the files and the robotfile from the spot selector in an compressed file. The compressed file has to be a .tgz-, .tar.gz-, .tar- or .zip-file. Also you have to observe that the compressed file has to be from a special form. This tool uploads all files at once and connect them automatically with the right gel spot. At the moment it only works for Maldi-Files.
How to use
At first you have to import a gel-picture and select the spots you want to analyse. In the config-file you find the the directories where the ms-files for one spot have to be saved (normally the mass spectrometer does it automatically). Be aware that the config file has to be in a specific format, described below. Now you need to save the config-file as geometry.config. After you selected the spots and send them into the mass spectrometer, you have to create a workstep for ms import and select all samples(spots) that were used by the spot selector.Than you will see all your selected samples, normally with the name SpotPicking(X). Now you can click on "Import Scan" and you will be forwarded to the Mass Spectra Data site. Here you find two sections: "Mass Spectra Browser" and "Mass Spectra Importer". In the second field (Mass Spectra Importer) you choose "Maldi" for the mass spectra type (it doesn't work correctly for Esi-files at the moment) and select "many" for the number of files. Now you can browse and and insert your file into the file-window. After you click on "Import", the system starts importing the file. The file has to be a .tgz-, .tar.gz-, .tar- or .zip-file otherwise there will be an error. For the format of the file see the section below. The system automatically connects every maldi file with the corresponding sample. After you imported the file, you can select a sample from the field (Mass Spectra Browser) above and you will see the mass spectrum for this sample.
If you want to make a search with mascot or emowse against a database, you have to return to the Experiment Editor by clicking on the link on the left site of the web-page. There you click on Experiment Selection and choose the link Mass Spectra Data. From there you select MS for scan type and choose one or more scans for the search. To get to the search form you have to click on the "Peptide Mass Fingerprint" link.
Formats
Format of the Config File
The config file has to be in a special format. Only than connection between the files and the samples can be made correctly. First of all, it is important that you save the config file, after you selected the spots on the gel, with the name "geometry.config". Here is an example for a config file with 14 spots in it:
Comment_1 Pos_on_Scout AutoX_Method Spectrum_Directory Spectrum_Filename Probe_Geometry Chip_on_Scout ************ ************ ************ ************ ************ ************ ************ standard A:1 calibrate_sbd Standard_A1 1 probe A:1 measure_sbd I_A_01 0 probe B:1 measure_sbd I_B_01 0 standard C:1 calibrate_sbd Standard_C1 1 probe C:1 measure_sbd I_C_01 0 probe D:1 measure_sbd I_D_01 0 standard E:1 calibrate_sbd Standard_E1 1 probe E:1 measure_sbd I_E_01 0 probe F:1 measure_sbd I_F_01 0 standard G:1 calibrate_sbd Standard_G1 1 probe G:1 measure_sbd I_G_01 0 probe H:1 measure_sbd I_H_01 0 probe A:2 measure_sbd I_A_02 0 probe B:2 measure_sbd I_B_02 0 probe C:2 measure_sbd I_C_02 0 probe D:2 measure_sbd I_D_02 0 probe E:2 measure_sbd I_E_02 0 probe F:2 measure_sbd I_F_02 0
This is a standart config file. It is automatically generated by ProDB. It is important that there is only the name of the Spectrum_Directory in the config file (forth tab) and not the whole path. Furthermore each row containing a spot has to start with the word probe and every row containing a calibration has to start with something else (default is standart). Normally, if you take the autogenerated file you don't have to change anything. Try to change as little as possible in the file.
Format of the compressed File
First create a directory,
Author: Nicole de la Chaux